LAC LABTECH (South Korea) benchtop autoclaves

21.12.2021
3.8K
Description:
  • Sterilization temperature +110°C and +135°C Water filling - heating - sterilization - venting - natural drying - end of cycle
  • Microprocessor controlled programmable PID controller with auto-adjustment and LCD display
  • 3 pre-set programs: for packed objects, for unpacked objects, sterilization of liquids. One user programmable
  • Fully automatic operating system with display of workflow parameters on LCD makes it easy to control the cycle from start to finish
  • Pressure relief valve prevents overpressure in the chamber, thermostat prevents overheating and a normally open solenoid valve keeps the chamber at ambient pressure
  • Self-diagnosis and safety. In the event of a malfunction, operation is automatically interrupted for safety reasons, the sterilizer contents are vented and an error code is shown on the display for easy service
  • Fast sterilization at 134°C for 5 minutes
  • Efficient displacement volume ensures maximum sterilization capacity
 
 
Specifications* of models LAC-3012SE, LAC-3012SV
Model
 
LAC-3012SE
 
LAC-3012SV
 
Class
 
N
 
B
 
Air Removal.
 
Gravity
 
Vacuum pump
 
Capacity, l
 
415x345x560
 
Internal dimension, mm
 
200х200х300
 
Capacity, l
 
12
 
Controller
 
Microprocessor PID controller
 
*Specification is subject to change without notice to improve quality.
 
 
Specifications* of models LAC-2010E, LAC-2020E, LAC-2030E
Model
 
LAC-2010E
 
LAC-2020E
 
LAC-2030E
 
Controller
 
Microprocessor PID controller with manual settings
 
Model
 
LA C- 3010G
 
LAC-3020G
 
LAC-3030G
 
Controller
 
Microprocessor 3 pre-set programs, 1 user program
 
External dimensions, (WxHxV) mm
 
480х720х400
 
530x780x420
 
650х820х500
 
Internal dimension, (DIAM x D), mm
 
200х350
 
250х450
 
350х455
 
Volume, l
 
11
 
22
 
44
 
Water tank volume, l
 
5
 
5
 
7
 
Heater capacity, kW
 
1,5
 
2
 
3
 
Outer surface material
 
Epoxy coated steel
 
Chamber material
 
Stainless steel (STS 316 L steel optional)
 
Sterilization temperature
 
101 to +135°C
 
Pressure range
 
0.39 to 2.25 bar
 
Vacuum/pressure range
 
-0.1 to 0.4 MPa (760 mm Hg - 4 kgf/cm2)
 
Display
 
LED (temperature, timer, cycle programming)
 
LED (water, heating, sterilization, drying, end of cycle.)
 
Timer
 
4-90 min. in sterilization mode and 1-90 min. in drying mode
 
Door
 
Single action closure / Inter Lock system
 
Safety
 
  • Pressure relief valve 
  • Protection against overheating 
  • Door opening and power cut off sensor 
  • Low water level protection 
  • Current and leakage protection
Trays
 
175х330
 
215х405
 
305х435
 
Wire cable trays (standard) / Perforated trays (optional)
 
Power supply
 
110 V, or 220 V, 50/60 Hz.
 
 
 
*Specifications subject to change without notice to improve quality.
 
 
 
  • Cycles for sterilization
  • Starting
  • Filling with water 
  • heating 
  • sterilisation 
  • venting 
  • natural drying 
  • end of cycle